Equipment database
- Name:
- Spectrofluorimeter
- Producer:
- Edinburgh
- Model:
- FS 900 CDT, FL 900 CDT
- Research group:
- Team 29. Photophysics and spectroscopy of photoactive systems: structure and reactivity of systems with hydrogen bonds
- Description:
-
The Edinburgh spectrofluorimeter with two possible geometries - L and T measures stationary fluorescence spectra and fluorescence excitation of 200-900 nm; equipped with polarizers; Time-resolved measurements are possible - measurement of fluorescence life in the range from ns to μs.
- Contact:
mgr Maria Pszona
Research
- Type of measurement: Study of electron-vibron structure
- Test method: Fixed fluorescence spectrum
Details
- Name of equipment: Edinburgh model: FS 900 CDT, FL 900 CDT
- Type of measurement: Study of electron-vibron structure
- Test method: Fixed fluorescence spectrum
- Measurement range from: 200 nm
- Measurement range to: 900 nm
- Average measurement time: 5 days
- User performing the measurement: mgr Maria Pszona
- Type of measurement: Study of electron-vibron structure
- Test method: Fixed fluorescence excitation spectrum
Details
- Name of equipment: Edinburgh model: FS 900 CDT, FL 900 CDT
- Type of measurement: Study of electron-vibron structure
- Test method: Fixed fluorescence excitation spectrum
- Opis:
Correction curve in the range 200-600 nm, in the range of 600 -900 nm measurement possible without correction to the excitation spectrum of the tube
- Measurement range from: 200 nm
- Measurement range to: 900 nm
- Average measurement time: 5 days
- User performing the measurement: mgr Maria Pszona
- Type of measurement: Study of quantum efficiency
- Test method: Fixed fluorescence spectrum
Details
- Name of equipment: Edinburgh model: FS 900 CDT, FL 900 CDT
- Type of measurement: Study of quantum efficiency
- Test method: Fixed fluorescence spectrum
- Measurement range from: 200 nm
- Measurement range to: 900 nm
- Average measurement time: 5 days
- User performing the measurement: mgr Maria Pszona
- Type of measurement: Study of kinetics of processes in excited states
- Test method: Measurement of lifetime in ns
Details
- Name of equipment: Edinburgh model: FS 900 CDT, FL 900 CDT
- Type of measurement: Study of kinetics of processes in excited states
- Test method: Measurement of lifetime in ns
- Opis:
Excitation with 337 nm wavelength
- Measurement range from: 200 nm
- Measurement range to: 900 nm
- Average measurement time: 5 days
- User performing the measurement: mgr Maria Pszona
- Type of measurement: Study of kinetics of processes in excited states
- Test method: Measurement of lifetime in µs
Details
- Name of equipment: Edinburgh model: FS 900 CDT, FL 900 CDT
- Type of measurement: Study of kinetics of processes in excited states
- Test method: Measurement of lifetime in µs
- Measurement range from: 200 nm
- Measurement range to: 900 nm
- Average measurement time: 5 days
- User performing the measurement: mgr Maria Pszona